Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T10BU00919

Parcel: 10601247B


Addresses:

266 E PASTIME RD


Inspection Status: Approved

Inspection History: GRADING - FINAL

Permit Number - T10BU00919

Inspection Description - GRADING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/26/2012 GRADING - FINAL Approved AN AS-BUILT WAS SUBMITTED TO THE CITY OF TUCSON ALONG WITH A CERTIFICATION STATEMENT FROM THE ENGINEER OF RECORD. ALL REQUIRED ITEMS HAVE BEEN COMPLETED
05/14/2012 GRADING - FINAL Continued NO CHANGES AT THIS TIME
04/13/2012 GRADING - FINAL Continued SPOKE WITH PROJECT MANAGER ON THE PHONE. DISCUSSED FINAL APPROVAL FOR GRADING PERMIT.
03/23/2012 GRADING - FINAL Continued SPOKE WITH NEW SUPERINTENDENT, NOT READY FOR FINAL, WILL CALL FOR RE-INSPECTION ON MONDAY
03/09/2012 GRADING - FINAL Continued SPOKE WITH PROJECT MANAGER AND SUPERINTENDENT ABOUT DETAILS ON HC PARKING AND ACCESS ALONG THE EAST SIDE OF THE NEW BLDG.
03/05/2012 GRADING - FINAL Continued FOLLOW UP ON PUNCHLIST ITEMS FROM PREVIOUS INSPECTION.
03/01/2012 GRADING - FINAL Continued ITEMS # 5, 6, 8, AND 9 FROM THE PUNCHLIST GENERATED DURING THE 2/22/12 FINAL GRADING INSPECTION HAVE BEEN COMPLETED.
ITEM # 1 REQUIRES VERIFICATION PRIOR TO APPROVAL.
02/22/2012 GRADING - FINAL Denied 1) INSTALL HC ACCESS RAMP PER APPROVED GRADING PLAN, SEE NOTE #5A (NE CORNER).
2) INSTALL ROCK RIP RAP PER APPROVED GRADING PLAN AT SIDEWALK SCUPPER, SEE DETAIL "K", SHEET C0.1, TO INCLUDE TOE -DOWN WALL.
3) PROVIDE A CERTIFICATION STATEMENT FROM THE ENGINEER OF RECORD STATING THAT ALL CONSTRUCTED STORM DRAINAGE WAYS TO INCLUDE SUBGRADE ROOF DRAINAGE WAS SUBSTANTIALLY COMPLETED PER THE APPROVED PLAN.
4) SUBMITT A CERTIFIED AS-BUILT DRAWING TO THE CITY OF TUCSON.
5) REMOVE OLD SECTION OF SILT SOCK PLACED AT THE CHILD DROP OFF AREA.
6) HC PARKING SIGN ALONG WEST WALL OF WEST PARKING AREA HAS BEEN INSTALLED WITH NO PARKING SPOT AND/OR HC ACCESS RAMP.
7) HC PARKING AND ACCESS ALONG THE EAST SIDE OF THE BLDG. EXCEEDS THE 2% IN ANY DIRECTION SLOPE REQUIREMENT SHOWN ON YOUR APPROVED PLANS AND REQUIRED BY ADAAG/ANSI.
8) TWO MAIN ROOF DRAINS ALONG THE NORTH SIDE OF THE BLDG, DROP ONTO ATHE MAIN ACCESS SIDEWALK AND HC RAMP.
9) TRUNCATED DOMES AT HC CROSSING ALONG THE EAST SIDE OF THE BLDG ARE FACING THE WRONG DIRECTION.
10) PROVIDE A CITY OF TUCSON APPROVED GRADING PLAN FOR THE FINAL GRADING INSPECTION THAT SHOWS WHAT WAS BUILT OR CONSTRUCT THE SITE PER THE CITY OF TUCSON APPROVED GRADING PLAN.

CALL FOR RE-INSPECTION WHEN COMPLETED.
08/10/2011 GRADING - FINAL Denied SITE IS NO WHERE NEAR COMPLETION, HOWEVER CONTRACTOR CALLED IN FOR A FINAL INSPECTION.
SIDEWALKS NOT COMPLETE, STORM DRAIN BASINS NOT COMPLETE, PAVING NOT COMPLETE, OVERHEAD AWNING STRUCTURES NOT COMPLETE. TOO MANY ITEMS TO LIST THAT ARE LEFT TO DO.
SITE IS NOT SAFE FOR OCCUPANCY.