Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
Permit Number - T10BU00161
Inspection Description - POOL/SPA FINAL/BARRIER
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/14/2010 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection :* 1) NO SVRS |
|
04/09/2010 | POOL/SPA FINAL/BARRIER | Not ready for Inspection | IVRS - Inspection :* 1) AS OF 8 AM THIS MORNING 4/9/10-NO APPROVED LISTING WAS RECEIVED. MR. MAJUTA MY SUPERVISOR TALKED WITH ME ABOUT THIS MATTER. THE E-MAIL DID NOT CONTAIN A U.L. APPROVAL FOR (SPECIFY J-BOX REQUIREMENTS) IT IS A U.L. LISTED POOL PANEL, BUT NO LISTING SUPPLIED FOR USE AS DIRECT CONNECTION FROM A WET NICHE FIXTURE. IF YOU RECEIVE COPY OF APPROVAL, PLEASE LEAVE WITH YOUR JOB SITE PAPERWORK |
|
04/06/2010 | POOL/SPA FINAL/BARRIER | Partial Approval | IVRS - Inspection :* OK TO PEBBLE TEC IF V.L. LISTING IS OBTAINED 1ST |
|
03/31/2010 | POOL/SPA FINAL/BARRIER | Not ready for Inspection | IVRS - Inspection :* 1) ANTI/SIPHON ON HOSE BIB 2) BOND JUMPERS AT AL. FENCE SECTIONS 3) NEED U.L. LISTING FOR USE OF SUB PANEL AS DIRECT CONNECTION TO LIGHT FIXTURE |