Permit: T09PL02158

Parcel: 114465490

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/31/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
12/30/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CORRECT DRIP AT CW SOV FOR WATER HEATER
2) REMOVE SHEETROCK TO 1" AROUND B-VENT, INSTALL VENT DRAFT COLLAR LEVEL WITH ALL SIDES SET ON WATER HEATER
3) SOAD TEST GAS CONNECTIONS
12/29/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) INTERIOR REPIPE ONLY
2) OK TO COVER
3) REPLACE PB LAV SUPPLIES
4) RECONNECT ALL FIXTURES AND WATER TEST-RECALL FOR FINAL APPROVAL
12/24/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
INTERIOR REPIPE ONLY:
1) PROVIDE 18" OF METALLIC TUBING WHERE SOLDERING MAY OCCUR
2) POLY B AT DISHWASHER
3) SECURE TUBING FOR MANUFACTURES INSTRUCTIONS
4) BLOCK NIPPLE AT REAR HB
5) SECURE SHOWER VALVE
6) READ PEX INSTALLATION INSTRUCTIONS
7) OPEN DRAIN PIPES SHOULD BE CAPPED DURING CONSTRUCTION