7420 E 42ND ST


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T09PL02135

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
01/11/2010 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
12/30/2009 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
1. BONDING TO BE DONE TO BUILDING GAS PIPING THAT IS NOT COATED PIPING. THE INNER LINER OF THE DOUBLE WALL VENT PIPE AT THE CONNECTION TO THE SINGLE WALL VENT PIPE IS BROKEN LOOSE AND THIS CONNECTION POINT MUST BE CONNECTED PROPERLY PER NOT #1 ABOVE.

2. CUT THE T&P RELIEF DRAIN PIPE 1" ABOVE TOP LIP OF PAN PER NOTE #2 ABOVE.

3. CONTRACTOR TO PAY REINSPECTION FEE & RECALL FOR INSPECTION

PRESSURE TEST OK, OK TO BURY YARD PIPING
12/24/2009 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*