Permit: T09PL02014

Parcel: 126062450


Addresses:

720 N IRVING CI

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/08/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
12/03/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
GAS FLEX CANNOT PASS THROUGH THE WATER HEATER ENCLOSURE. DOUBLE WALL VENT ON WATER HEATER IS UPSIDE DOWN & NEEDS 1" CLEARANCE FROM CUBUSTIBLES AT ROOF PENETRATION.
PROVIDE MINIMUM 3 SCREWS IN ALL JOINTS OF VENT CONNECTORS.
REMOVE ALL FOIL TAPE FROM VENTS.
FURNACE VENT CONNECTOR JOINTS UPSIDE DOWN, NO SCREWS.
PROVIDE ELECTRICAL BOND TO GAS PIPING.
PROVIDE A MAX OF 15LBS PRESSURE GUAGE.
OK TO REUSE STAINLESS STEEL 6' GAS FLEX AT STOVE.