Permit: T09PL01950

Parcel: 132091760


Addresses:

2601 E PINAL VISTA


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T09PL01950

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
11/09/2010 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
11/01/2010 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) PROVIDE APPROVED FLUE VENT WATER HEATER
2) PROVIDE CSA APPROVED VALVES AND FLEXES FOR STOVE AND FURNACE
3) CLEANOUT TRENCH FROM METER TO HOUSE
02/09/2010 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) PROVIDE MINIMUM 10 PSI TEST ON ALL GAS PIPING
2) COMPLETE GAS PIPING FOR WATER HEATER WITH CSA APPROVED GAS VALVE AND FLEX
3) PROVIDE VALVE AND FLEX FOR STOVE
4) PROVIDE SUPPORT ON ALL GAS PIPING