Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/19/2012 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 11/05/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE APPROVED COUPLING IN UNDERGROUND PIPING, PROVIDE PRIMER AND TAPE 2) PROVIDE SUPPORT ON WALL FOR GAS PIPING TO WATER HEATER AND DRYER ROOM 3) COMPLETE INSTALL OF WATER HEATER AND PROVIDE APPROVAL CSA GAS VALVE AND FLEX 4) PROVIDE APPROVED CSA GAS VALVES AND FLEX FOR STOVE 5) PROVIDE SUPPORT ON GAS PIPING AT FURNACE AND CARPORT FLUE VENT |