Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/03/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) GAS CARD AT METER |
|
| 11/02/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) HAVE AN ELECTRICAL INSPECTION ADDED TO THIS PERMIT FOR NEW CIRCUIT TO RANNI WATER HEATER WITH DISCONNECT 2) PROVIDE APPROVED CLEARANCES FOR WATER HEATER 3) PROVIDE T & P DRAIN TERMINATION 4) PROVIDE CORRECT FURNACE VENT TERMINATION MINIMUM 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF INTAKE 5) COMPLETE WATER PIPING TO RANNI AND PROVIDE INSULATION ON PIPING EXPOSED TO FREEZING |