Permit: T09PL01756

Parcel: 124082280


Addresses:

1332 E 10TH ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
11/05/2009 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
11/04/2009 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE NOTES FROM 1332 E. 10TH ST:
1) TEST TO BE AT 10 PSI AND HOLDING USING AT TEST GAUGE IN 1/10 POUND INCREMENTS, HOLDING PRESSURE FOR MINIMUM 15 MINUTES WITH NO LOSS OF PRESSURE
2) SEAL PIPE PENETRATIONS INTO BLDG
3) PROVIDE BONDING FO BLDG GAS SYSTEM