Permit: T09PL01688

Parcel: 130071990


Addresses:

3732 E 25TH ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T09PL01688

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/20/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
10/16/2009 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) GAS CLEARANCE REQUIRED
2) CARPORT VENT CONNECTOR; REMOVE TAPE, MAKE JOINTS PROPERLY AND SECURE WITH GALVANIZED SHEET METAL SCREWS
3) RECALL FOR FINAL APPROVAL
10/15/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) 11 PSI TEST OK
2) PROVIDE AN APPROVED T & P DRAIN WITH PROPER TERMINATION
3) PLUMB AND SECURE VENT CONNECTOR
4) PROVIDE PROPER B VENT TERMINATION
5) EXTEND NIPPLE AT STOVE CONNECTION SO THAT FLEX IS NOT INSIDE FIRE BOX
6) PROVIDE ELECTRICAL BONDING OF GAS SYSTEM