Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T09PL01688
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/20/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
10/16/2009 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1) GAS CLEARANCE REQUIRED 2) CARPORT VENT CONNECTOR; REMOVE TAPE, MAKE JOINTS PROPERLY AND SECURE WITH GALVANIZED SHEET METAL SCREWS 3) RECALL FOR FINAL APPROVAL |
|
10/15/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) 11 PSI TEST OK 2) PROVIDE AN APPROVED T & P DRAIN WITH PROPER TERMINATION 3) PLUMB AND SECURE VENT CONNECTOR 4) PROVIDE PROPER B VENT TERMINATION 5) EXTEND NIPPLE AT STOVE CONNECTION SO THAT FLEX IS NOT INSIDE FIRE BOX 6) PROVIDE ELECTRICAL BONDING OF GAS SYSTEM |