Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T09PL01673

Parcel: 130151530


Addresses:

4634 E SYLVANE ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
11/13/2009 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
1) MECH UNIT WILL BE INSPECTED BY MECHANICAL T09CM02810
10/14/2009 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) 15 PSI TEST OK
2) SUPPORT AND SECURE PIPING OVER HEAD
3) REMOVE TAPE AT B VENT CONNECTION, SECURE VENT W/3 SCREWS PER JOINT
4) T & P TERMINATION IS 6"-24" ABOVE GROUND
5) ALL NEW WORK REQUIRES PERMITS
NOTE:
THIS IS A SINGLE FAMILY RES AND IS VACANT AT THIS TIME