Permit: T09PL01663

Parcel: 122184560


Addresses:

3817 E LEE ST #B

Inspection Status: Partial Approval

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/15/2009 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) PIPING IS OK
2) PROVIDE THE FOLLOWING CORRECTIONS AT WATER HEATER INSTALLED WITHOUT PERMIT
3) INSTALL A PAN OR REMOVE WOOD PLATFORM
4) PROVIDE APPROVED MATERIALS FOR T & P
5) PROVIDE SEDIMENT TRAP
6) REMOVE TAPE AND SECURE WATER HEATER VENT CONNECTOR
7) PROVIDE A PERMIT FOR WATER HEATER AND FURNACE
10/13/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*