Permit: T09PL01657

Parcel: 136072740


Addresses:

9419 E 26TH ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
10/21/2009 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
10/20/2009 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
10/16/2009 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) TEST TO HOLD 10 PSI MIN FOR 15 MINUTES
2) PROVIDE APPROVEDF 90 DEGREE (MALLABLE IRON) NO CAST IRON
3) PROVIDE PIPE PRIMER THEN TAPE ALL UNDERGROUND FITTINGS AND TOOL MARKS TO ACHIEVE 40 MIL WRAP
4) PROVIDE ROOF FLASHING AT ROOF PENETRATION AND MAKE IT WEATHER TIGHT
5) COMPLETE GAS PIPING TO WATER HEATER/FURNACE APPROVED GAS SHUT OFF VAVLES AND SECURE THIS PIPING IN CLOSET
6) PROVIDE BONDING OF GAS SYSTEM
7) RESEAL RETURN AIR PLENIUM