Permit: T09PL01620

Parcel: 125073260


Addresses:

420 N OLSEN AV


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T09PL01620

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
10/14/2009 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
1) UNITS #420 AND 424 RELEASED FOR GAS
2) OK TO COVER UNDERGROUND ON ALL THREE UNITS
10/09/2009 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) THIS INSPECTION FOR UNIT #420 ONLY TEST OK
2) CAP OR PLUG OLD PIPING IN RESIDENCE
3) VENT FROM WATER HEATER TO BE APPROVED TYPE THRU ROOF TO POINT OF TERMINATION AND BE MADE UP CORRECTLY TO DRAFT HOOD
4) WATER HEATER REQUIRES APPROVED BASE SUPPORT (WOOD IS NOT) AND WEATHER PROOF ENCLOSURE
5) PIPING TO BE PROPERLY SHADED FOR CONTINOUS SUPPORT IN TRENCH
6) PROVIDE BONDING OF BLDG GAS SYSTEM
7) SEAL PIPING PENETRATIONS AND HOLE INTO STRUCTURE
8) GAS IS ON TO UNIT #422
9) COMPLETE PIPING TO UNIT #424
10) NOTES PERTAIN TO ALL UNITS