| 10/14/2009 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* 1) UNITS #420 AND 424 RELEASED FOR GAS 2) OK TO COVER UNDERGROUND ON ALL THREE UNITS |
|
| 10/09/2009 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1) THIS INSPECTION FOR UNIT #420 ONLY TEST OK 2) CAP OR PLUG OLD PIPING IN RESIDENCE 3) VENT FROM WATER HEATER TO BE APPROVED TYPE THRU ROOF TO POINT OF TERMINATION AND BE MADE UP CORRECTLY TO DRAFT HOOD 4) WATER HEATER REQUIRES APPROVED BASE SUPPORT (WOOD IS NOT) AND WEATHER PROOF ENCLOSURE 5) PIPING TO BE PROPERLY SHADED FOR CONTINOUS SUPPORT IN TRENCH 6) PROVIDE BONDING OF BLDG GAS SYSTEM 7) SEAL PIPING PENETRATIONS AND HOLE INTO STRUCTURE 8) GAS IS ON TO UNIT #422 9) COMPLETE PIPING TO UNIT #424 10) NOTES PERTAIN TO ALL UNITS |