Permit: T09PL01568

Parcel: 128110770


Addresses:

5026 E JULIA ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/07/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
09/30/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) TEST TO HOLD ON ENTIRE GAS PIPING SYSTEM WITH NO PRESSURE LOSS FOR 15 MINUTES
2) INSTALL GAS SHUT OFF VALVE FOR BBQ & CAP
3) TURN ON FIREPLACE VALVES AND CAP PIPE INSIDE HEARTH OF FIREPLACE FOR ENTIRE SYSTEM TEST
4) SUPPORT GAS PIPE AT WATER HEATER
5) EXTEND WATER HEATER VENT PIPING WITH DBL WALL VENT PIPING TO 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER AND REINSTALL VENT CAP