Permit: T09PL01536

Parcel: 11107192A


Addresses:

3222 E GLENN ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/18/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
12/17/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE BONDING NOT GROUNDING OF BLDG GAS SYSTEM
12/16/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) NEW WATER HEATER REQUIRES TEMPERATURE AND PRESSURE RELIEF DRAIN PIPE (COPPER, GALV, CPVC MATERIAL) TERMINATING AT DOWNWARD DIRECTION 6" TO 24" FROM FINISH GRADE
2) PROVIDE DBL WALL VENT PIPING FROM WATER HEATER THRU ROOF PROPERLY FLASHED AT ROOF LEVEL WITH CORRECT VENT CAP
3) PROVIDE SEDIMENT TRAP AT GAS ENTRY TO WATER HEATER
4) PROVIDE BONDING OF METALIC BLDG GAS PIPING
5) PROVIDE A PERMANENT CAP AT STOVE VALVE LOCATION IF GAS STOVE IS NOT USED