Permit: T09PL01440

Parcel: 137070870


Addresses:

5133 S LOSTAN AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/03/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
09/01/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE 18" OF COVER ON UNDERGROUND PE PIPING
2) PROVIDE GAUGE IN 1/10 PSI INCREMENTATION MINIMUM 10 PSI TEST
3) PROVIDE CSA APPROVAL GAS VALVE AT HOUSE
4) PROVIDE TRACER WIRE ON ALL UNDERGROUND GAS PIPING
5) UNION MUST BE 6" ABOVE SOIL
6) GAS FLEX CANNOT GO THRU SIDE WALL OF WATER HEATER CLOSET
7) PROVIDE APPROVED FLUE VENT AND CAP FOR WATER HEATER
8) PROVIDE SUPPORT ON WALL FOR GAS PIPING TO WATER HEATER