Permit: T09PL01363

Parcel: 117063000


Addresses:

131 N HOFF AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T09PL01363

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/23/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
1) OK FOR GAS
2) UCC'S LEFT AT METER
08/17/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) FLEX CONNECTOR MAY NOT PASS THRU WALL OR PARTITION 131, 133 T & P RELIEF MAY NOT DSCHARGE UNDER HOUSE
2) VERTICAL PIPING TO BE SUPPORTED
3) UNDER HOUSE PIPING NOT SUPPORTED PER 2006 UPC
4) PROVIDE ACCESS TO FURNACE
08/12/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) GAS PIPING SHALL NOT BE INSTALLED IN OR ON THE GROUND UNDER ANY BLDG, BUT SHALL BE KEPT AT LEAST 6" ABOVE GRADE
2) UNIONS MAY NOT BE INSTALLED AT INACCESSIBLE LOCATIONS. NOT INSTALLED PER PLAN
3) ALL PIPING TO BE SUPPORTED PER 2006 UPC
4) WATER HEATER AND FURNACE REQUIRE SEDIMENT TRAPS
5) WATER HEATER REQUIRES T & P RELIEF DRAIN
6) UNABLE TO ENTER #131