Permit: T09PL01149

Parcel: 131130260

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/27/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
07/17/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
07/07/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) 10 PSI TEST REQUIRED ON SYSTEM
2) NEW WATER HEATER REQUIRES A PERMIT AND THE FOLLOWING CORRECTIONS:
T & P MAY NOT REDUCE IN SIZE
WATER FLEXES ARE KINKED
SEDIMENT TRAP REQUIRED IN ACCESSIBLE LOCATION
BUSHINGS MAY NOT BE CONCEALED
PROPER SLOPE ON VENT CONNECTOR AND PROPER TEE FITTING AT COMMON VENT
REMOVE ALL TAPE AND CORRECT ALL JOINTS
SECURE WITH GALV SCREWS
GALVANIZED FITTINGS NOT ALLOWED ON COPPER SYSTEM
COMBUSTION AIR REQUIRED
FLEX TO FURNACE IS TOO SMALL FOR 75000 BTU
SEAL WALL PENETRATIONS
ELECTRICAL BONDING REQUIRED