Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/09/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* GAS CARD AT METER - SW METER @ 889-1888 PROVIDE BONDING - PROVIDE 90 DEG. DOWN ON TERMINATION OF T&P DRAIN AT EXTERIOR |
|
| 06/08/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE CLAMPS FOR PIPING ON ROOF TO BLOCKS 2. CAP OLD GAS PIPING 3. SECURE DROP AT FURNACE/WATER HEATER LOCATION 4. PROVIDE 6" MINIMUM CLEARANCE FOR SINGLE WALL VENT PIPING FROM COMBUSTIBLES 5. PROVIDE FASTENERS AT ALL JOINTS OF VENT CONNECTOR PIPING 6. WATER HEATER TEMPERATURE AND PRESSURE RELIEF SHALL GRAVITY DRAIN 7. PROVIDE BONDING FOR BUILDING GAS PIPING |