Permit: T09PL00967

Parcel: 125041230


Addresses:

2146 E 1ST ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/24/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
1) CORRECTIONS HAVE BEEN MADE
09/23/2009 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) LEFT GAS CARD
2) 13 PSI TEST IS OK
3) PROVIDE DBL WALL VENT PIPE WITH AN APPROVED CAP FOR WATER HEATERS
4) PROVIDE MINIMUM 1/4" PER FT. SLOPE ON VENT CONNECTOR
09/21/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) NO ONE HOME UNABLE TO DO INSPECTION 1:50 PM
09/11/2009 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) CORRECT SLOPE ON T & P
2) NEED TO SEE PERMIT FOR FURNACE
3) GAS CLEARANCE PROVIDED
09/09/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
PROVIDE ACCESS TO ROOF
PROVIDE A PERMIT FOR NEW ROOF TOP MECHANICAL UNITS. (#2148 ALSO REQUIRES PERMITS)
PIPING REQUIRES FLASHINGS
TEST DOWN. CHECK FOR LEAKS
NEW WH REQUIRES NEW GAS FLEX. ALSO 50V FOR WH ONLY
07/31/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO MESSAGE, NO ACCESS AT 9:30 AM