Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/03/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) GAS CARD ON PIPE AT ? |
|
| 10/30/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE #6 FROM 5/29/09 |
|
| 06/12/2009 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEE NOTE #5, #6 AND COMPLETE INSTALLATION TO RECEIVE GAS CARD |
|
| 06/04/2009 | PLUMBING - FINAL | Cancelled | IVRS - RI canceled | |
| 05/29/2009 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE AN EMERGENCY GAS SHUT OFF VALVE AT BUILDING SERVICE ENTRY BECAUSE METER IS IN REMOTE LOCATION. 2. VENT PIPING FOR FURNACE IS REQUIRED TO BE INSTALLED WITH FITTINGS IN CORRECT DIRECTION OF VENT GAS FLOW 3. WATER HEATER IS NOT ON A SAFE, STABLE ASSEMBLY (LEGS DAMAGED WOOD SHIMS) 4. SEAL PIPE PENETRATIONS INTO BUILDING 5. PROVIDE COMBUSTION AIR FOR WATER HEATER & FURNACE AREA - NOTE: NO DOOR DOES NOT MEET THE REQUIREMENT IF AND WHEN A DOOR IS INSTALLED. THE REQUIREMENT NEEDS TO BE MET NOW 6. WHERE IS THE DRYER VENT? IT MUST BE VENTED. |