Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T09PL00830
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/15/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* OK TO COVER W/CLEAN FILL |
|
05/13/2009 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REMOVE ROCKS 2) PROVIDE PROPER SHADING MATERIAL AROUND PEX 3) SECURE TRACER WIRE 8' ON CENTER PER STATE LAW AND SECURE TO RISER 24" ABV GRADE 4) SUPPORT PIPING AT NEW BACKFLOW 5) PROVIDE A TUCSON WATER BACKFLOW PERMIT AND SUBMIT TEST REPORT TO TUCSON WATER |