Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T09PL00830

Parcel: 12901014B


Addresses:

2310 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T09PL00830

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/15/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
OK TO COVER W/CLEAN FILL
05/13/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REMOVE ROCKS
2) PROVIDE PROPER SHADING MATERIAL AROUND PEX
3) SECURE TRACER WIRE 8' ON CENTER PER STATE LAW AND SECURE TO RISER 24" ABV GRADE
4) SUPPORT PIPING AT NEW BACKFLOW
5) PROVIDE A TUCSON WATER BACKFLOW PERMIT AND SUBMIT TEST REPORT TO TUCSON WATER