Permit: T09PL00603

Parcel: 116193700

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T09PL00603

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/22/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
04/09/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SUPPORT EXPANSION TANK
2. IF WATER HEATER IS ON ELEVATED PLATFORM SUBJECT TO DAMAGE A DRIP PAN IS REQUIRED
3. WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN PIPING SHALL GRAVITY DRAIN TO DAYLIGHT OR APPROVED RECEPTOR TERMINATING AT 90 DEG. DOWN
PLEASE VERIFY AND PROVIDE POINT OF TERMINATION