Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/22/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 05/21/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CONTRACTOR CANCELLED |
|
| 05/20/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. SEPARATE PERMIT HAS BEEN PULLED FOR ELECTRICAL - OK 2. SECURE SINKS, PROVIDE GRATES ON FLOOR SINKS 3. PROVIDE MIN. 1" AG AT SANITIZE COMP. 4. INSTALL FRANK PATTERN CO COVERS. 5. EXPOSE ALL CO's SHOWN ON PLAN 6. SEAL THREADS ON CLEANOUTS 7. RECIRCULATING HW SYSTEM REQUIRES INSULATION AND IS SPECIFIED ON PLAN 8. PROVIDE ACCESS TO HIGH CEILING AND ROOF 9. TRAP & TRAP ARM SHALL BE THE SAME SIZE 10. FOLLOW PIPING DETAIL AND NOTES 11. LIST MAY NOT BE COMPLETE. |
|
| 05/19/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* COMPLETE ALL WORK ALSO, SEE PREVIOUS INSP. HISTORY PROVIDE CORRECT USE OF FITTINGS CALL IN ALL INSP. ON ACTIVITY CARD |