Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/22/2009 | PLUMBING - ROUGH, SOIL | Approved | ||
| 04/27/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* PIPE WRAPS AND FLOOR SINKS INSTALLED, RUN TEST ON INTERCEPTOR TIE IN TO BLD. SEWER OK 1. PROVIDE FRANK PATTERN CLEANOUTS IN CONCRETE FLOOR AREAS AND IN SIDEWALKS FOR TRAFFIC AREAS (PEDESTRIAN RATED PER PLAN) |
|
| 04/24/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER TEST THRU BLD. WITH CLEANOUTS TO 10' ONLY TO INTERCEPTOR WITH VENT OK 1. PROVIDE EXTERNAL TRAP ON DISCHARGE END OF INTERCEPTOR WITH FLOW TEST 2. HAVE PIPE WRAPS AND FLOOR SINKS FOR PRE-SLAB PRIOR TO CONCRETE INSPECTION. |
|
| 04/21/2009 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. REMOVE ALL MOISTURE FROM DISCHARGE AREA OF INTERCEPTOR TO VERIFY NO LEAKAGE 2. VENTS BELOW FLOOD RIM OF FIXTURE TO BE LONG RADIUS DRAINAGE FITTINGS 3. PROVIDE 1O' HEAD TEST ON BOTH PIPING SYSTEMS GREASE AND SANITARY 4. EXPOSE FITTINGS & PIPING ON BOTH SYSTEMS (GREASE AND SANITARY) 5. POINT OF VENT TO BE MINIMUM OF CENTER LINE OF DRAIN FOR HORIZONTAL VENTING AND REQUIRES LONG RADIUS FITTINGS BELOW FLOOD RIM OF FIXTURE 6. WHERE ARE THE FLOOR CLEANOUTS PER APPROVED PLAN 7. PROVIDE INFORMATION ON GREASE INTERCEPTOR FOR FLOW CONTROL AND SIZE 8. WHERE IS DOWNSTREAM CLEANOUT FOR GREASE DISCHARGE PER PLAN 9. INSTALL TEST FITTINGS OK CLEANOUTS FOR INTERMEDIATE DWV TEST THRU ROOF OR YOU WILL BE REQUIRED TO RETEST UNDERGROUND AGAIN 10. APPROVED EXTENSION TO GRADE IS REQUIRED FOR INTERCEPTOR LIST MAY NOT BE COMPLETE |
|
| 04/09/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER TEST FROM POINT OF CONNECTION TO EXISTING 4" SEWER UPSTREAM TO 3" CLEANOUT IN SIDEWALK ONLY REVISED APPROVED PLAN IS REQUIRED FOR CITY OF TUCSON |
|
| 04/08/2009 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. INSTALL 2-WAY CLEANOUT PER PLAN 2. PROPERLY BED YOUR PIPING SO IT IS ON A FIRM BED NO BRIDGING OR USE OF ROCKS TO SUPPORT PIPING. |