Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T09PL00465


Addresses:

2821 E AIRPORT DR


Inspection Status: Approved

Inspection History: SITE - SEWER

Permit Number - T09PL00465

Inspection Description - SITE - SEWER

Inspection Status - Approved

Date Description Inspector Results Comments
05/21/2010 SITE - SEWER Approved IVRS - Inspection :*
12/03/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
PROVIDE DOCUMENTATION FROM PCDEQ FOR DISCHARGES FOR ???
11/06/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) VACUUM TESTING MANHOLES TESTING BEING DONE BY JENSEN AND DOCUMENTATION BEING DONE BY DAVE FROM SANTEC #7 MANHOLE (DIDNOT PASS TEST) WILL CHECK WITH DAVE AFTER ALL TESTING IS DONE ABOUT OTHER MANHOLES
11/05/2009 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
11/04/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) AIR TESTING ? ? BY AATR FOR ALL SDR 35 FROM MANHOLE TO MANHOLE
2) STAN TEE TAKING DOCUMENTATION FOR ALL TESTING
11/03/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) MANDOOR TESTING BEING DONE BY AA&R, STANTEC DOING DOCUMENTATION
10/30/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) PIPING IN TO MAN HOLE #15 BEDDED TRACER WIRE SDR35 OK
2) TO BE TESTED AT A LATER DATE (PIPING AND MANHOLE)
10/28/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 201 NORTH OF MAN HOLE #15 SDR35 TRACER WIRE BEDDING OK, TO BE TESTED AT LATER DATE
10/26/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 150' TO THE SOUTH OF MAN HOME #14 SPR 35 TRANS WIRE BUILDING OK
2) TO BE TESTED AT LATER DATE
10/21/2009 SITE - SEWER Partial Approval IVRS - Inspection :*1) 300' EAST OF MAN HOLE #13 SDR 35 BUILDING & TH---WIRE OK TO BE TESTED AT LATER DATE.
10/20/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 240' EAST OF MAN HOLE 33 TRACER WIRE BEDDING SDR-35 OK
2) TO BE TESTED AT LATER DATE
10/16/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) STUB IN TO MANHOLE #13 SDR 35 TRACER WIRE BEDDING, OK TO BE ? ? ? ?
10/15/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) PIPING SDR35 TRACER WIRE BEDDING 40' NORTH OF MAN HOLD #13
10/13/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) STUB IN TO MAN HOLE #12 SDR35 TRACER WIRE AND BEDDING OK
10/08/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 100' SOUTH OUT OF MAN HOLE #11 BEDDING TRACER WIRE SDR 35 OK
2) TO BE TESTED AT LATER DATE
10/07/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 28' OUT OF MANHOLE #11 SDR 35 BEDDING TRACER WIRE, OK TO BE TESTED AT LATER DATE
10/02/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 150' OUT TO THE SOUTH OF MAN HOLE #10 BEDDING TRACER WIRE 8" SDR 35 OK
09/30/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
09/11/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 240' SOUTH OF #9 MANHOLE BEDDING TRACER WIRE OK
2) TO BE TESTED AT LATER DATE
09/10/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 220' OUT OF MAN HOLE #9 SOUTH TRACER WIRE BEDDING OK
09/09/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
09/08/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 80' SOUTH OUT OF MAN HOLE #9 SDR 35 BEDDING TRACER WIRE OK
2) TESTING TO BE DONE AT LATER DATE
09/04/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 14' SOUTH OF MAN HOLE #9 SDR 35 TRACER WIRE AND BEDDING OK
2) TO BE TESTED AT LATER DATE
09/03/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
SDR 35 8" TRACER WIRE BEDDING OK UP TO MANHOLE #9
09/02/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) SDR 35 TRACER WIRE AND BEDDING 80' NORTH OF MAN HOLE #9 OK
09/01/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 250 DEGREE FROM MANHOLE #8 8" DIP
2) TRACER WIRE BEDDING OK TO BE TESTED AT A LATER DATE
08/31/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) INSTALLING 8" DIP SP2000 APX 250' SOUTH OF MAN HOLE #8 2) BEDDING AND TRACER WIRE OK
08/28/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) FROM MAN HOLE #8 SDR 35 8" AND DIP 8" 200' BEDDING AND TRACER WIRE OR TEST TO BE DONE AT LATER DATE
08/26/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
08/25/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 8 SDR 35 BEDDING AND TRACER WIRE OK 60' FROM MAN HOLE #8
2) TO BE TESTED AT LATER DATE
08/21/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 8" CONTINUES APP. 150' FROM MANHOLE #7 TO #8 BEDDING, LAYING AND TRACER ?
08/20/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
8" SDR CONTINUOUS APP. 100' FROM MANHOLE #7 TOWARD #8
BEDDING, LAYING, TRACER, SHADE
08/19/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) MANHOLE BASES #5 & #6 POURED THIS AM
2) PIPING CONTINUES FROM MANHOLE #7 APP. 28' TOWARD MANHOLE #8, BEDDING LAYING, TRAILER AND SHADE
08/18/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) PIPING CONTINUES TO 14' FROM MAN HOLE 37 BEDDING, LAYING AND TRACER SHADEING
08/17/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 8" SDR 35 CONTINUES FROM MANHOLE #6 TO STATION 3775 APP 100' FROM MANHOLE #7 BEDDING LAYING, TRACER AND SHADING
08/12/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 8" SDR 35 CONTINUES TO MANHOLE #6 BEDDING, TRACER, PIPING CONTINUES APP 28' TOWARD MANHOLE #7
08/07/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) HEADING SOUTHEAST 200' FROM MANHOLE #5 TRACER WIRE
2) BEDDING OK
3) TO BE TESTED AT LATER DATE
08/06/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) FROM MAN HOLE #5 130' TO ? SOUTHEAST BEDDING
2) TRACER WIRE SDR35 OK. TO BE TESTED AT LATER DATE
08/05/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
08/04/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 20' NORTH OF MANHOLE 35 TRACER WIRE BEDDING SDR 35 8"-OK
05/20/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1. TESTING PIPING FROM MANHOLE #16 TO MANHOLE #17
TEST OK (ONLY)
2. VACUUM TESTING MANHOLE #16 OK (ONLY)
3. STANTEC HAS TEST PAPERWORK
05/15/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
SDR35 TRACER WIRE BEDDING FROM
MANHOLE #4 ABOUT 150' FROM MANHOLE #5 OK
05/14/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 84' SOUTH OF MAN HOLE #4
05/13/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) SDR 35 TRACER WIRE AND ? OK 28' NORTH OF MAN HOLE #4
05/12/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
GO TO MANHOLE 4 -- 150' AWAY
05/11/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1. SDR35 TRACER WIRE BEDDING OK UP TO GATEHOUSE
2. ALL TESTING TO BE DONE AT LATER DATE
05/08/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
SOUTH OUT OF MANHOLE #3
70' SDR35 TRACER WIRE BEDDING OK
05/06/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
8" SDR 35 CONTINUOUS FROM MANHOLE #2 TO APP. 150' FROM MANHOLE #3, BEDDING, LAYING, TRACER, SHADING
05/05/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1. DIP STUB INTO MANHOLE #2
2. SDR35 STUB OUT 28' OF MANHOLE #2
05/04/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1. INSTALLING DIP THRU WASH BEDDING TRACER WIRE OK
2. ALL TESTING TO BE DONE ON LATER DATE
05/01/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
SDR35 BEDDING TRACER WIRE UP TO STATION 13 + 00 OK
04/30/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
FROM MANHOLE #1 SOUTH 64' SDR35 8' TRACER WIRE AND BEDDING OK
04/29/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
STUB OUT OF EXISTING MANHOLE #16 42' SOUTH
SDR 35 TRACER WIRE BEDDING OK
04/28/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
REMOVE OLD CLAY STUB OUT OF MANHOLE
JUST SOUTH OF STREET
04/27/2009 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
HIT WATER MAIN -- CITY WATER ON SITE
04/20/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
STACKING MANHOLE #16
04/17/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
SDR35 FROM MANHOLE #16 TO #17 BEDDING TRACER WIRE
04/16/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
GOING SOUTH 30' FROM MANHOLE #17 BEDDING
TRACER WIRE SDR35 OK
04/15/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
WORKING ON FIRST SDR35 COMING OUT OF MANHOLE #16
04/14/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) SDR-35 FROM MAN HOLE #15 FROM MAN HOLE #16 ? ? AND BLDG OK
04/10/2009 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
04/09/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
SDR35 SOUTHEAST FROM MANHOLE #15
56' TRACER WIRE AND BEDDING OK