Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: SITE - SEWER
Permit Number - T09PL00465
Inspection Description - SITE - SEWER
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/21/2010 | SITE - SEWER | Approved | IVRS - Inspection :* | |
12/03/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* PROVIDE DOCUMENTATION FROM PCDEQ FOR DISCHARGES FOR ??? |
|
11/06/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) VACUUM TESTING MANHOLES TESTING BEING DONE BY JENSEN AND DOCUMENTATION BEING DONE BY DAVE FROM SANTEC #7 MANHOLE (DIDNOT PASS TEST) WILL CHECK WITH DAVE AFTER ALL TESTING IS DONE ABOUT OTHER MANHOLES |
|
11/05/2009 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* | |
11/04/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) AIR TESTING ? ? BY AATR FOR ALL SDR 35 FROM MANHOLE TO MANHOLE 2) STAN TEE TAKING DOCUMENTATION FOR ALL TESTING |
|
11/03/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) MANDOOR TESTING BEING DONE BY AA&R, STANTEC DOING DOCUMENTATION |
|
10/30/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) PIPING IN TO MAN HOLE #15 BEDDED TRACER WIRE SDR35 OK 2) TO BE TESTED AT A LATER DATE (PIPING AND MANHOLE) |
|
10/28/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 201 NORTH OF MAN HOLE #15 SDR35 TRACER WIRE BEDDING OK, TO BE TESTED AT LATER DATE |
|
10/26/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 150' TO THE SOUTH OF MAN HOME #14 SPR 35 TRANS WIRE BUILDING OK 2) TO BE TESTED AT LATER DATE |
|
10/21/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :*1) 300' EAST OF MAN HOLE #13 SDR 35 BUILDING & TH---WIRE OK TO BE TESTED AT LATER DATE. | |
10/20/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 240' EAST OF MAN HOLE 33 TRACER WIRE BEDDING SDR-35 OK 2) TO BE TESTED AT LATER DATE |
|
10/16/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) STUB IN TO MANHOLE #13 SDR 35 TRACER WIRE BEDDING, OK TO BE ? ? ? ? |
|
10/15/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) PIPING SDR35 TRACER WIRE BEDDING 40' NORTH OF MAN HOLD #13 |
|
10/13/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) STUB IN TO MAN HOLE #12 SDR35 TRACER WIRE AND BEDDING OK |
|
10/08/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 100' SOUTH OUT OF MAN HOLE #11 BEDDING TRACER WIRE SDR 35 OK 2) TO BE TESTED AT LATER DATE |
|
10/07/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 28' OUT OF MANHOLE #11 SDR 35 BEDDING TRACER WIRE, OK TO BE TESTED AT LATER DATE |
|
10/02/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 150' OUT TO THE SOUTH OF MAN HOLE #10 BEDDING TRACER WIRE 8" SDR 35 OK |
|
09/30/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* | |
09/11/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 240' SOUTH OF #9 MANHOLE BEDDING TRACER WIRE OK 2) TO BE TESTED AT LATER DATE |
|
09/10/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 220' OUT OF MAN HOLE #9 SOUTH TRACER WIRE BEDDING OK |
|
09/09/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* | |
09/08/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 80' SOUTH OUT OF MAN HOLE #9 SDR 35 BEDDING TRACER WIRE OK 2) TESTING TO BE DONE AT LATER DATE |
|
09/04/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 14' SOUTH OF MAN HOLE #9 SDR 35 TRACER WIRE AND BEDDING OK 2) TO BE TESTED AT LATER DATE |
|
09/03/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* SDR 35 8" TRACER WIRE BEDDING OK UP TO MANHOLE #9 |
|
09/02/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) SDR 35 TRACER WIRE AND BEDDING 80' NORTH OF MAN HOLE #9 OK |
|
09/01/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 250 DEGREE FROM MANHOLE #8 8" DIP 2) TRACER WIRE BEDDING OK TO BE TESTED AT A LATER DATE |
|
08/31/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) INSTALLING 8" DIP SP2000 APX 250' SOUTH OF MAN HOLE #8 2) BEDDING AND TRACER WIRE OK |
|
08/28/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) FROM MAN HOLE #8 SDR 35 8" AND DIP 8" 200' BEDDING AND TRACER WIRE OR TEST TO BE DONE AT LATER DATE |
|
08/26/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* | |
08/25/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 8 SDR 35 BEDDING AND TRACER WIRE OK 60' FROM MAN HOLE #8 2) TO BE TESTED AT LATER DATE |
|
08/21/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 8" CONTINUES APP. 150' FROM MANHOLE #7 TO #8 BEDDING, LAYING AND TRACER ? |
|
08/20/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 8" SDR CONTINUOUS APP. 100' FROM MANHOLE #7 TOWARD #8 BEDDING, LAYING, TRACER, SHADE |
|
08/19/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) MANHOLE BASES #5 & #6 POURED THIS AM 2) PIPING CONTINUES FROM MANHOLE #7 APP. 28' TOWARD MANHOLE #8, BEDDING LAYING, TRAILER AND SHADE |
|
08/18/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) PIPING CONTINUES TO 14' FROM MAN HOLE 37 BEDDING, LAYING AND TRACER SHADEING |
|
08/17/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 8" SDR 35 CONTINUES FROM MANHOLE #6 TO STATION 3775 APP 100' FROM MANHOLE #7 BEDDING LAYING, TRACER AND SHADING |
|
08/12/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 8" SDR 35 CONTINUES TO MANHOLE #6 BEDDING, TRACER, PIPING CONTINUES APP 28' TOWARD MANHOLE #7 |
|
08/07/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) HEADING SOUTHEAST 200' FROM MANHOLE #5 TRACER WIRE 2) BEDDING OK 3) TO BE TESTED AT LATER DATE |
|
08/06/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) FROM MAN HOLE #5 130' TO ? SOUTHEAST BEDDING 2) TRACER WIRE SDR35 OK. TO BE TESTED AT LATER DATE |
|
08/05/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* | |
08/04/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 20' NORTH OF MANHOLE 35 TRACER WIRE BEDDING SDR 35 8"-OK |
|
05/20/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. TESTING PIPING FROM MANHOLE #16 TO MANHOLE #17 TEST OK (ONLY) 2. VACUUM TESTING MANHOLE #16 OK (ONLY) 3. STANTEC HAS TEST PAPERWORK |
|
05/15/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* SDR35 TRACER WIRE BEDDING FROM MANHOLE #4 ABOUT 150' FROM MANHOLE #5 OK |
|
05/14/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 84' SOUTH OF MAN HOLE #4 |
|
05/13/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) SDR 35 TRACER WIRE AND ? OK 28' NORTH OF MAN HOLE #4 |
|
05/12/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* GO TO MANHOLE 4 -- 150' AWAY |
|
05/11/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. SDR35 TRACER WIRE BEDDING OK UP TO GATEHOUSE 2. ALL TESTING TO BE DONE AT LATER DATE |
|
05/08/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* SOUTH OUT OF MANHOLE #3 70' SDR35 TRACER WIRE BEDDING OK |
|
05/06/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 8" SDR 35 CONTINUOUS FROM MANHOLE #2 TO APP. 150' FROM MANHOLE #3, BEDDING, LAYING, TRACER, SHADING |
|
05/05/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. DIP STUB INTO MANHOLE #2 2. SDR35 STUB OUT 28' OF MANHOLE #2 |
|
05/04/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. INSTALLING DIP THRU WASH BEDDING TRACER WIRE OK 2. ALL TESTING TO BE DONE ON LATER DATE |
|
05/01/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* SDR35 BEDDING TRACER WIRE UP TO STATION 13 + 00 OK |
|
04/30/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* FROM MANHOLE #1 SOUTH 64' SDR35 8' TRACER WIRE AND BEDDING OK |
|
04/29/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* STUB OUT OF EXISTING MANHOLE #16 42' SOUTH SDR 35 TRACER WIRE BEDDING OK |
|
04/28/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* REMOVE OLD CLAY STUB OUT OF MANHOLE JUST SOUTH OF STREET |
|
04/27/2009 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* HIT WATER MAIN -- CITY WATER ON SITE |
|
04/20/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* STACKING MANHOLE #16 |
|
04/17/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* SDR35 FROM MANHOLE #16 TO #17 BEDDING TRACER WIRE |
|
04/16/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* GOING SOUTH 30' FROM MANHOLE #17 BEDDING TRACER WIRE SDR35 OK |
|
04/15/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* WORKING ON FIRST SDR35 COMING OUT OF MANHOLE #16 |
|
04/14/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) SDR-35 FROM MAN HOLE #15 FROM MAN HOLE #16 ? ? AND BLDG OK |
|
04/10/2009 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* | |
04/09/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* SDR35 SOUTHEAST FROM MANHOLE #15 56' TRACER WIRE AND BEDDING OK |
|
04/07/2009 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* |