Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/19/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 02/13/2009 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SECURE PIPING ABOVE WATER HEATER IN A MANNER THAT WILL ISOLATE THE PEX FROM TOUCHING METAL AND ABOVE TOILET ROOM TO PREVENT NOISE, UNTWIST HW AND CW LINES. PROVIDE 18" OF COPPER IN WALL BEHIND WH. PROVIDE APPROVED TYPE B VENT W/CORRECT TERMINATION ABOVE SWAMP COOLER. WILL ALSO REQUIRE AIRTIGHT ACCESS PANEL TO WH ROOM IN BEDROOM OK TO COVER WALLS EXCEPT AT CORRECTIONS |
|
| 02/10/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE LADDER FOR ABOVE CEILING AND ROOF 2. PROVIDE APPROVED FLOW VENT FOR WATER 3. PROVIDE PETITION OF APPEAL FOR WATER T&P FROM CITY OF TUCSON OR PIPE TO DAYLIGHT 4. LIST MAY NOT BE COMPLETE |