Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T09PL00179

Parcel: 123061220


Addresses:

2342 E ADAMS ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/04/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
01/29/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE A FUNCTIONAL TEMPERATURE & PRESSURE RELIEF DEVICE FOR WATER HEATER
2. VENT FROM WATER HEATER TO BE APPROVED MATERIAL THRU ROOF WITH APPROVED VENT TERMINATION
3. SUPPORT GAS PIPING ON ROOF AND IN WATER HEATER CLOSET

THIS IS NOT A GAS RECONNECT, IT APPEARS A NEW ROOF TOP UNIT IS INSTALLED