Permit: T09PL00166

Parcel: 11006007B

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T09PL00166

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/09/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
02/02/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
#1, #8 OK
#18 WATER HEATER IS LEANING AGAINST SIDE WALL AND VENT CAP APPEARS TO BE BLOCKING VENT TERMINATION
01/29/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
01/28/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
UNIT #1 (ONLY) TEST ON SYSTEM AND YARD PIPING OK
- NEW PIPING IS OK
- PROVIDE SUPPORT AT INLET
- WATER HEATER FLOOR IS DAMAGED FROM A
LEAKING T&P VALVE (505.6, 508.4)
2. T&P VALVE SHALL BE OPERATIONAL AND PROPERLY TERMINATED - VENT TERMINATIONS ARE LESS THAN 10' FROM COOLER 510.6.2.6 GAS SUPPLY TO EACH APPLIANCE IS NOT SECURED 1211.2.6