Permit: T09PL00113

Parcel: 106062270


Addresses:

924 W SIMMONS ST

Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Date Description Inspector Results Comments
01/26/2009 PLUMBING - YARD WTR LINE/TEST Approved IVRS - Inspection :*
01/23/2009 PLUMBING - YARD WTR LINE/TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ALL GAS PIPING ON ROOF MUST BE SECURED WITH A CLAMP
2) FURNACE EXHAUST STACK NEEDS TO BE EXTENDED TO CLOSE TO COOLER
3) NEED TO PUT TRACER WIRES IN TRENCHES
4) INSULATE AND SEAL ALL PENETRATIONS IN MECHANICAL ROOM
5) PIPING SCHEMATIC CALLS FOR 3/4" PIPE, NOT 1/2"-REVISE OR BUILD TO PLAN