Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T09PL00087

Parcel: 12316146A


Addresses:

1001 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/05/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
02/24/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. ONLY ONE SLIP NUT ALLOWED ON THE DISCHARGE OF THE TRAP TAILPIECE TO HAVE A SMOOTH INTERIOR WATER WAY.
2. JIM CAP NOT AN APPROVED CLEANOUT ADPT.
3. INDIRECT WASTE PIPING TO BE APPROVED MATERIAL INSTALLED IN A WORKMANSHIP LIKE MANNER AND SUPPORTED IN AN APPROVED FASHION.
4. NO BACKPITCH, NO WOOD
5. 90 DEG. TERMINATION
6. REWORKED, MODIFIED OR REINSTALLED EQUIPMENT TO MEET CURRENT CODE STANDARDS
01/26/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. OK TO COVER SEWER
2. OK TO COVER UNDER SLAB
3. OK TO COVER WALLS