Permit: T09PL00061

Parcel: 10512024E


Addresses:

4040 N ORACLE RD

Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Date Description Inspector Results Comments
08/25/2009 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection :*
03/27/2009 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
1. CONNECTIONS FROM MICHAELS AND BEAUTY COLLEGE TO MANHOLE MADE OK
2. OK TO COVER
03/26/2009 PLUMBING - SEWER HCS CONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE PROPER TRANSITION FITTINGS NO RESTRICTIONS
PROVIDE TEST
PROVIDE TRACER WIRE
PROVIDE CLEANOUT ON ADDITIONAL LINE
REDLINE ADDITIONAL LINES

10:10 AM
1. STILL FILLING
2. PROVIDE THRU WALL TO SCH40 ADAPTOR & PROPER ALIGNMENT AT ABS TO SDR
3. PROVIDE WEATHER RESISTANT WIRE NUTS
4. PROVIDE 1/4" SLOPE
5. CORRECT LEAK AT 3" TIE IN
6. MOVE C O FROM CURB
7. TWICE I HAVE BEEN TOLD THAT A TUB WAS READY, BUT WHEN I ARRIVED IT WAS NOT READY
03/20/2009 PLUMBING - SEWER HCS CONNECT Partial Approval AFTER HRS. INSP. TO BE BILLED TO
ADOLFSON PETERSON ACCT. - TWO HRS. $150.00

STREET CUT TO MANHOLE
TAPPED MANHOLE
INSTALL D.I.P
CONNECT TO D.I.P AT PROPERTY LINE
03/10/2009 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection :*
03/06/2009 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*