Permit: T09OT02078

Parcel: 12218232A


Addresses:

3601 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: FIRE - FINAL

Date Description Inspector Results Comments
11/02/2009 FIRE - FINAL Approved Approved
10/14/2009 FIRE - FINAL Denied 1.) Provide approved, accurate floor plans to include addition of rooms, walls and outside metal awning.
2.) Provide a readily visible sign over the main double doors that read," DOOR MUST REMAIN UNLOCKED WHEN THE BUILDING IS OCCUPIED"
3.) Repair /replace broken glass on front doors.
4.) Replace all missing cover plates.
5.) Provide thumb-turn locks to the doors leading into the main showroom area.
6.) Secure the integrity of the large rool-up glass doors in front of building.
7.) Cover all openings in walls and ceilings.
8.) Provide a thumb-turn lock for door leading into the office from the shop area or provide a sign for that door reading."NOT AN EXIT".
9.) Remove slide-bolt and pad lock from outside bathroom doors.
10.) Remove the side-bolt from the rear exit door.
11.) Need a breaker blank, outside electrical panal.
12.) Remove the EXIT sign located next to the metal rool-up door, back side of building.
13.) Cube adaptors are prohibited.