Permit: T09OT01453

Parcel: 124051780


Addresses:

1118 E 6TH ST

Inspection Status: Approved

Inspection History: CERTIFICATE OF OCCUPANCY

Date Description Inspector Results Comments
07/28/2009 CERTIFICATE OF OCCUPANCY Approved IVRS - Inspection :*
07/17/2009 CERTIFICATE OF OCCUPANCY Not ready for Inspection IVRS - Inspection :*
1) LEVER HANDLE HARDWARE REQUIRED ON ALL COMMON DOORS
2) FLEX GAS LINE MAY NOT GO INTO WALL AT WATER HEATER (NEED NIPPLE AND VALVE ACCESSIBLE)
3) RP BACKFLOW ASSEMBLY REQUIRED FOR SODA COMPRESSORS
4) ALL INDIRECT WAST TO FLOOR DRAINS MUST TERMINATE 1" ABOVE FLOORD RIM
5) ON 3 COMPARTMENT SINK THE TWO MAIN DRAINS NEED TO BE DIRECTLY WATED WITH SANITIZER, SINK IN-DIRECTLY WASTED