Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS RECONNECT
Permit Number - T09MH00044
Inspection Description - PLUMBING - GAS RECONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/22/2009 | PLUMBING - GAS RECONNECT | Approved | IVRS - Inspection :* 1) T & P RELIEF DRAIN TO BE APPROVED MATERIAL AND TERMINATED OUTSIDE MOBILE HOME 2) WATER HEATERS AND FURNACES REQUIRE SEDIMENT TRAPS 3) WATER HEATER REQUIRE A VALVE AT THE COLD INLET 4) CALL 03090 FOR FINAL 5) OK TO BACKFILL |
|
08/27/2009 | PLUMBING - GAS RECONNECT | Not ready for Inspection | IVRS - Inspection :* FRONT UNIT: 1) PROVIDE A PRESSURE TEST, A MOBILE HOME RATED FLEX AND AN OPERATIONAL T & P AT EXISTING WATER HEATER REAR UNIT: 1) AT NEWER WATER HEATER, INSTALL A PAN, A SEDIMENT TRAP AND TERMINATE T & P COMBUSTION AIR |