Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/30/2010 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 02/23/2010 | MECHANICAL - INTERMEDIATE | Partial Approval | NOTES FOR 3549 E. BELLEVUE ST: 1) OK FOR SHEETROCK ------------------------------------------------------------------------------------------------- NOTES FOR 3551 E. BELLEVUE ST: 1) ATTIC INSULATION CANNOT BE ABOVE GABLE END VENTS 2) PROVIDE MIN R8 DUCT IN ATTIC 3) PROVIDE BACKING AROUND CEILING BOXES 4) SUPPORT EXHAUST DUCT 5) EXTEND DRYER VENT THRU WALL |
|
| 01/22/2010 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) PROVIDE R-8 MIN. INSULATION ON ALL DUCT EXPOSED TO EXTERIOR INCLUDING DUCT IN VENTED ATTIC SPACE 2) EXHAUST DUCT NOT MECHANICALLY FASTENED 3) PROVIDE PROPER WIRE SIZE ON UNIT LINE VOLTAGE 4) UNIT DATA PLATE NOT IDENTIFIED 5) CONDENSATE PVC TO BE PRIMED AT ALL JOINTS. PRIMER TO BE PURPLE IN COLOR 6) PROVIDE BREAKER FOR UNIT |
|
| 01/11/2010 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ONE ON SITE 2) PROVIDE ROOF ACCESS |