Permit: T09ME00103

Parcel: 110061290


Addresses:

3932 E HAYHURST LN

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
07/29/2009 MECHANICAL - FINAL Approved IVRS - Inspection :*
05/04/2009 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
PROVIDE SCREEN IN T-TAPS ON ROOF
INSTALL KITCHEN HOODS AND GRILLES
03/23/2009 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
03/20/2009 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. NO COMBUSTIBLE MATERIALS ALLOWED IN RETURN PLENUM
2. ALL PVC PIPING MUST USE PRIMER (PURPLE IN COLOR) PRIOR TO GLUE
3. PVC NOT ALLOWED IN RETURN PLENUM AS IT IS CONSIDERED A NON-PLENUM RATED MATERIAL
4. RTU's NOT INSPECTED