Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FULL
Case Number - T09FR03694
Inspection Description - INSP - FULL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/30/2009 | INSP - FULL | Approved | abated | |
12/07/2009 | INSP - FULL | Correction Required | Goodyear Auto Service Center ATTN: Michael Albrecht 8280 E. 22nd St Tucson, AZ. 85710 Dear Mr. Albrecht The Tucson Fire Department has conducted a fire safety inspection at the above stated business on December 7, 2009. Below is a list of violations that shall be corrected to provide compliance with the applicable codes, regulations and ordinances. Compliance is required by the 2006 International Fire Code (with modifications). A Re-inspection will be performed on or about December 21, 2009 Notice of Violations: _____ 906.7 Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied Required Action: All fire extinguishers shall be properly mounted: - Tire storage area - Bay #5 _____ 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes: Required Action: Replace the missing electrical cover-plate in the conference room _____ 1008.1.8.3 Locks and latches. Exit doors shall be openable from the egress side without use of a key or any special knowledge of effort. Required Action: Rear exit door shall have a thumb-latch. Remove double-key locking hardware _____ 504.2 Maintenance of exterior doors and openings. Exterior doors and their function shall not be eliminated without prior approval. Exterior doors that have been rendered nonfunctional and that retain a functional door exterior appearance shall have a sign affixed to the exterior side of the door with the words THIS DOOR BLOCKED. The sign shall consist of letters having a principal stroke of not less than 0.75 inch (19.1mm) wide and at least 6 inches (152 mm) high on a contrasting background Required Action: Provide proper signage _____ 105.6.16 #3 Flammable and combustible liquids. An operational permit is required to… store, handle or use Class II or Class IIIA or class IIIB liquids in excess of 25 gallons (95 L) in a building or in excess of 60 gallons (227 L) outside a building, except for fuel oil used in connection with oil-burning equipment. Required Action: Obtain permits for your AST's (3 ea tanks n property). _____ 407.2 Material Safety Data Sheets. Material Safety Data Sheets (MSDS) for all hazardous materials shall be readily available on the premises. _____ 407.4 Training. Persons responsible for the operation of areas in which hazardous materials are stored, dispensed, handled or used shall be familiar with the chemical nature of the materials and the appropriate mitigating actions necessary in the event of a fire, leak or spill… Required Action: Train employees on the location of the MSDS/ Hazardous Communication Program. The Tucson Fire Department is committed to the protection of your property. Your help as a business owner and as a citizen is greatly appreciated. |