Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FULL
Case Number - T09FR03440
Inspection Description - INSP - FULL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/01/2009 | INSP - FULL | Approved | abated | |
11/16/2009 | INSP - FULL | Approved | ||
11/02/2009 | INSP - FULL | Correction Required | Flash Automotive, Inc ATTN: Becky Harrington 8150 E. 22nd St. Tucson, AZ. 85710 Dear Mrs. Harrington The Tucson Fire Department has conducted a fire safety inspection at the above stated business on November 2, 2009. Below is a list of violations that shall be corrected to provide compliance with the applicable codes, regulations and ordinances. Compliance is required by the 2006 International Fire Code (with modifications). A Re-inspection will be performed on or about November 16, 2009 Notice of Violations: 1._____ 906.7 Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied - Required Correction: Fire extinguisher on the table shall be properly mounted. 2. _______1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. - Require Action: Remove locking device on rear doors and provide for unhindered egress 3._____ 1008.1.8.3 Locks and latches. In buildings in occupancy Group A having an occupant load of 300 or less, Groups B, F, M and S, and in churches, the main exterior door or doors are permitted to be equipped with key-operated locking devices from the egress side provided: 2.1. The locking device is readily distinguishable as locked, 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25mm)high on a contrasting background. 4._____ 605.5 Extension Cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances: - Required Correction: i. Remove extension cord at front desk ii. Remove extension cord going through wall in the shop area The Tucson Fire Department is committed to the protection of your property. Your help as a business owner and as a citizen is greatly appreciated. |