Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T09FR02880

Parcel: 12618217A


Addresses:

4110 E 22ND ST


Inspection Status: Violation

Inspection History: INSP - FULL

Case Number - T09FR02880

Inspection Description - INSP - FULL

Inspection Status - Violation

Date Description Inspector Results Comments
08/12/2009 INSP - FULL Violation TFC 605.1 - Abatement of electrical hazards.
Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the code official responsible for enforcement of the ICC Electrical Code. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used.

_____ Terminate exposed wiring under back sink in an approved manner

TFC 605.4 - Multiplug adapters.
Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with the ICC Electrical Code shall be prohibited.

_____ Office

TFC 605.4.1 - Power tap design.
Relocatable power taps shall be of the polarized or grounded type, equipped with overcurrent protection, and shall be listed in accordance with UL 1363.

_____ Griddle area


TFC 107.1 - Maintenance of safeguards.
Whenever or wherever any device, equipment, system, condition, arrangement, level of protection, or any other feature is required for compliance with the provisions of this code, or otherwise installed, such device, equipment, system, condition, arrangement, level of protection, or other feature shall thereafter be continuously maintained in accordance with this code and applicable referenced standards.

_____ Exit Sign Illumination - Dining room X2

_____ Repair Exit Sign - Back Door

_____ Repair Emergency Light - Dining Room X3

Chapter 906, Portable Fire Extinguishers
TFC 906.2 - General requirements.
Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.

_____ Recharge or remove extinguisher in office


TFC 904.11.6.3 - Cleaning
Hoods, grease-removal devices, fans, ducts and other appurtenances shall be cleaned at intervals necessary to prevent the accumulation of grease. Cleanings shall be recorded, and records shall state the extent, time and date of cleaning. Such records shall be maintained on the premises.

_____ Clean hood system and keep records of periodical cleanings.

904.11.4.1 Listed sprinklers. Sprinklers used for the protection of fryers shall be tested in accordance with UL 199E, listed for that application and installed in accordance with their listing.

_____ Install 3rd nozzle to provide coverage for 3 fryers or provide plans showing that the coverage is sufficient.

_____ Lower nozzles protecting griddle to provide coverage under back shelf.

Chapter 906, Portable Fire Extinguishers
TFC 906.2 - General requirements.
Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.

_____ Recharge or remove extinguisher in office.