Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FULL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/18/2009 | INSP - FULL | Approved | Approved/Abated 09/18. | |
| 08/27/2009 | INSP - FULL | Correction Required | FIRE INSPECTION REPORT 08-26-2009 Quick Mart #19 7667 E Escalante Tucson, AZ Dear Sir or Madam, The Tucson Fire Department has conducted a fire safety inspection at the above stated business on 08-26-2009. Below is a list of violations that shall be corrected to provide compliance with the applicable codes, regulations and ordinances. Compliance is required by the 2006 International Fire Code with modifications. A Re-inspection will be performed on or about September 10th 2009. 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. " The rear emergency exit shall have the padlock removed immediately. 703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance-rated assemblies shall be protected by self- or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. " Repair holes in walls and replace the damaged ceiling tiles to prevent the travel of smoke and flame in case of a fire. 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. " Replace the broken outlet cover outside. 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily operable from the egress side without the use of a key or special knowledge or effort. " Install a thumb latch on the front door in place of the double keyed lock. 3804.3 Container location. Containers shall be located with respect to buildings, public ways, and lot lines of adjoining property that can be built upon, in accordance with Table 3804.3. " The LPG must remain ten feet from the exit door. Re-Inspected by __________________ Approved Disapproved Sincerely, Conrad Funke Fire Inspector Tucson Fire Department 797 E. Ajo Tucson, AZ 85713-5011 (520) 791-4502 Ext. 102 |