Case: T09FR02664

Parcel: 13421088A


Addresses:

7020 E BROADWAY BL

Inspection Status: Violation

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
08/12/2009 VIOL - MEANS OF EGRESS Violation ___Exit door has double keyed locks.

1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.

***Remove double keyed lock. A thumblatch can be installed provided: the sign stating:
"Door shall remain unlocked during business hours" is replaced with a new sign stating:
"Door shall remain unlocked while building is occupied".