Inspection Status: Violation
Inspection History: VIOL - FLAMMABLE FINISHES
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/24/2009 | VIOL - FLAMMABLE FINISHES | Violation | IFC.1504.2 Location of spray-finishing operations. Spray finishing operations conducted in buildings used for Group A, E, I or R occupancies shall be located in a spray room protected with an approved automatic sprinkler system installed in accordance with Section 903.3.1.1 and separated vertically and horizontally from other areas in accordance with the International Building Code. In other occupancies, spray-finishing operations shall be conducted in a spray room, spray booth or spraying space approved for such use. ____Stop work ordered issued for automible spray painting. |