Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T09FR02374

Parcel: 12701004C

Inspection Status: Correction Required

Inspection History: INSP - SELF INSPECTION PROGRAM

Case Number - T09FR02374

Inspection Description - INSP - SELF INSPECTION PROGRAM

Inspection Status - Correction Required

Date Description Inspector Results Comments
07/20/2009 INSP - SELF INSPECTION PROGRAM Correction Required 2. IFC 315.2.1: Ceiling clearance. Storage shall be maintained 2 feet (610 mm) or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches (457 mm) below sprinkler head deflectors in sprinklered areas of buildings.
07/20/2009 INSP - SELF INSPECTION PROGRAM Correction Required 2. IFC 605.5: Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances
07/20/2009 INSP - SELF INSPECTION PROGRAM Correction Required 1. IFC 1008.1.8.3 #2.2: A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background