Case: T09FR02327

Parcel: 12705077B


Addresses:

4702 E SPEEDWAY BL


Inspection Status: Approved

Inspection History: INSP - FULL

Case Number - T09FR02327

Inspection Description - INSP - FULL

Inspection Status - Approved

Date Description Inspector Results Comments
08/03/2009 INSP - FULL Approved Corrections complete
07/16/2009 INSP - FULL Correction Required 07-16-2009
4702 East Speedway.
Tucson, AZ
Circle K #1798

Dear Sir or Madam,

The Tucson Fire Department has conducted a fire safety inspection at the above stated business on 07-16-2009. Below is a list of violations that shall be corrected to provide compliance with the applicable codes, regulations and ordinances. Compliance is required by the 2006 International Fire Code with modifications. A Re-inspection will be performed on or about July 30th 2009.


703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated.
Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance-rated assemblies shall be protected by self- or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly.

" Replace the tile in the hallway area to prevent the travel of smoke and flame in case of a fire.


901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective.

" Fire extinguishers shall be inspected annually and shall be mounted no less than 4 inches off the floor and no more than 4 feet. The front extinguisher needs serviced.



1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily operable from the egress side without the use of a key or special knowledge or effort.

" Install a thumb latch on the front door in place of the double keyed lock.


1003.6 Means of egress continuity. The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of a means of egress system shall not be diminished along the path of egress travel.

" Keep the exit path behind the store clear of obstructions.