Inspection History Details
Inspection Status: Correction Required
Inspection History: VIOL - MEANS OF EGRESS
Case Number - T09FR02017
Inspection Description - VIOL - MEANS OF EGRESS
Inspection Status - Correction Required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/22/2009 | VIOL - MEANS OF EGRESS | Correction Required | IFC 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background. _____1. Post the wording "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" above both main entrance doors. |
|
| 06/22/2009 | VIOL - MEANS OF EGRESS | Correction Required | IFC 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. _____1. The double-keyed lock located on the office door shall be replaced with a thumb-turn lock. _____2. The double-keyed lock located on the Pro Shop door shall be replaced with a thumb-turn lock. _____3. The double-keyed locks located on the west EXIT doors shall be disabled to prevent their use. _____4. Remove the locking hasp from the west end storage door. _____5. The double-keyed locks located on the east EXIT doors shall be disabled to prevent their use. _____6. The double-keyed lock located on the east end meeting room door shall be replaced with a thumb-turn lock. |
|
| 06/22/2009 | VIOL - MEANS OF EGRESS | Correction Required | IFC 1008.1.8.5 Unlatching. The unlatching of any door or leaf shall not require more than one operation. _____1. Remove the old drop-bar hardware from the east door located in the back machine area. |
|
| 06/22/2009 | VIOL - MEANS OF EGRESS | Correction Required | IFC 1027.3 Exit sign illumination. Exit signs shall be internally or externally illuminated. The face of an exit sign illuminated from an external source, shall have an intensity of not less than 5 foot-candles (54 lux). Internally illuminated signs shall provide equivalent luminance and be listed for the purpose. _____1. The EXIT sign located in the east end meeting room shall be illuminated. _____1. Replace the burned out bulb in the EXIT sign located above the lounge west exit door. |
|
| 06/22/2009 | VIOL - MEANS OF EGRESS | Correction Required | IFC 1027.5 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. In the event of power supply failure, illumination shall be automatically provided from an emergency system for the following occupancies where such occupancies require two or more means of egress: _____1. Repair the emergency lighting unit located by the pool tables. _____2. Repair the emergency lighting unit located by the front desk. |