Case: T09FR02007

Parcel: 13323190A


Addresses:

7790 E SPEEDWAY BL


Inspection Status: Correction Required

Inspection History: VIOL - FIRE RESIST.RATED CONST

Case Number - T09FR02007

Inspection Description - VIOL - FIRE RESIST.RATED CONST

Inspection Status - Correction Required

Date Description Inspector Results Comments
06/22/2009 VIOL - FIRE RESIST.RATED CONST Correction Required 703.1 Maintenance
The required fire-resistance-rated construction shall be maintained. Such elements shall be repaired, restored, or replaced when damaged, altered, breached, or penetrated.

_____ Fix, repair, or restore all openings or holes in the fire resistive walls

703.1 Maintenance.
The required fire-resistance rating of fire-resistance-rated construction (including walls, fire-stops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire

_____ Fix and repair all openings or holes in the ceiling

Call Inspector Pursley at 235-4709 or 791-4502, if you have any further questions.
Thank you.

Re-inspection passed: _____________________ ___/___/___