Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FULL
Case Number - T09FR01794
Inspection Description - INSP - FULL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/22/2009 | INSP - FULL | Approved | ||
06/08/2009 | INSP - FULL | Continued | Locks not removed before inspection. Spoke to Quick Mart GM, all discrepencies will be corrected | |
05/18/2009 | INSP - FULL | Correction Required | FIRE INSPECTION REPORT 05-19-2009 Quick Mart #29 3095 East Irvington Tucson, AZ Dear Sir or Madam, The Tucson Fire Department has conducted a fire safety inspection at the above stated business on 05-18-2009. Below is a list of violations that shall be corrected to provide compliance with the applicable codes, regulations and ordinances. Compliance is required by the 2006 International Fire Code with modifications. A Re-inspection will be performed on or about June 4th 2009. 1011.1 Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in a corridor is more than 100 feet (30 480 mm)or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. " After review of the stores plans and Certificate of Occupancy, this building has an occupant load of 63 which requires two exits. The rear emergency exit shall have the padlock removed immediately and an exit sign installed by the time of re-inspection. 1011.5.3 Power source. Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702 of the International Building Code. " The front Exit sing back up power does not work. 605.3Working space and clearance. A working space of not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be provided in front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the working space shall not be less than the width of the equipment. No storage of any materials shall be located within the designated working space. " Maintain the required distance. |