Inspection History Details
Inspection Status: Approved
Inspection History: VIOL - MEANS OF EGRESS
Case Number - T09FR01116
Inspection Description - VIOL - MEANS OF EGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/03/2009 | VIOL - MEANS OF EGRESS | Approved | ||
04/01/2009 | VIOL - MEANS OF EGRESS | Violation | 1027.16.7 Maintenance. Fire escapes shall be kept clear and unobstructed at all times and shall be maintained in good working order. ____Repair fire escape on west side of building. Currently has a loose handrail. |
|
04/01/2009 | VIOL - MEANS OF EGRESS | Violation | ||
04/01/2009 | VIOL - MEANS OF EGRESS | Violation | 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: 4. Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch, dead bolt or security chain, provided such devices are openable from the inside without the use of a key or tool. ____Remove the drop bar brackets from bedroom #10. These types of locking devices are prohibited. |
|
04/01/2009 | VIOL - MEANS OF EGRESS | Violation | 1027.5 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. In the event of power supply failure, illumination shall be automatically provided from an emergency system for the following occupancies where such occupancies require two or more means of egress: 8. Group R-2. Exception: Where each dwelling unit or sleeping unit has direct access to the outside of the building at grade. 1027.3 Exit sign illumination. Exit signs shall be internally or externally illuminated. The face of an exit sign illuminated from an external source, shall have an intensity of not less than 5 foot-candles (54 lux). Internally illuminated signs shall provide equivalent luminance and be listed for the purpose. ____Install emergency lighting units. They must be installed so they illuminate the entire means of egress in the event of a power failure. ____Install exit signs on front/main and rear exit. They must be internally or externally illuminated. |